Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 1.308
Filtrar
1.
Ideggyogy Sz ; 77(3-4): 89-96, 2024 Mar 30.
Artigo em Húngaro | MEDLINE | ID: mdl-38591929

RESUMO

Background and purpose:

The management of central retinal artery occlusion (CRAO) has long been conservative therapy with limited efficacy carried out in ophthalmology departments together with etiolo­gi­cal investigations lacking a standardised protocol. However, CRAO is analogous to ischemic central nervous system stroke and is associated with increased stroke risk, thus, systemic thrombolysis treatment and multidisciplinary management can be beneficial. Since May 2022, at Semmelweis University CRAO patients diagnosed within 4.5 hours are given intravenous thrombolysis therapy and undergo etiologic workup based on current stroke protocols. Here we report our experience with the multidisciplinary, protocol-based management of CRAO in comparison with former non-protocol based ophthalmological conservative treatment.

. Methods:

We reviewed CRAO patients’ data treated conservatively and with paracentesis within 6 hours at the Department of Ophthalmology between 2013 and 2022 including changes in visual acuity, neurolo­gical and cardiovascular findings compared to those in the thrombolysis project. 

. Results:

Of the 78 patients receiving non-protocol care, visual improvement was seen in 37% with natural course, 47% with conservative treatment and 47% with paracentesis. Four patients had significant carotid stenosis (2 underwent endarterectomy), 1 carotid dissection, 6 cardioembolism and 1 giant cell arteritis. Of the 4 patients within 4,5 hours, 3 gave their consent to the clinical trial and were treated with thrombolysis and underwent a full etiological assessment. 
2 pa­tients had improved visual acuity, 2 pa­tients had significant carotid stenosis and underwent endarterectomy, 1 patient was started on anticoagulation for newly diagnosed atrial fibrillation.

. Conclusion:

CRAO patients presenting within 4,5 hours are rare and more patients are needed in our study to establish the efficacy of thrombolysis. However uniform protocollized evaluation helps identifying embolic sources thus, avoiding further and potentially more serious thromboembolic events.

.


Assuntos
Estenose das Carótidas , AVC Isquêmico , Oclusão da Artéria Retiniana , Acidente Vascular Cerebral , Humanos , Terapia Trombolítica/métodos , Estenose das Carótidas/complicações , Estenose das Carótidas/terapia , Oclusão da Artéria Retiniana/tratamento farmacológico , Oclusão da Artéria Retiniana/diagnóstico , Acidente Vascular Cerebral/tratamento farmacológico , Tratamento Conservador
2.
J Med Imaging (Bellingham) ; 11(2): 026003, 2024 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-38606184

RESUMO

Purpose: Timely detection and treatment of visual impairments and age-related eye diseases are essential for maintaining a longer, healthier life. However, the shortage of appropriate medical equipment often impedes early detection. We have developed a portable self-imaging slit-light device utilizing NIR light and a scanning mirror. The objective of our study is to assess the accuracy and compare the performance of our device with conventional nonportable slit-lamp microscopes and anterior segment optical coherence tomography (AS-OCT) for screening and remotely diagnosing eye diseases, such as cataracts and glaucoma, outside of an eye clinic. Approach: The NIR light provides an advantage as measurements are nonmydriatic and less traumatic for patients. A cross-sectional study involving Japanese adults was conducted. Cataract evaluation was performed using photographs captured by the device. Van-Herick grading was assessed by the ratio of peripheral anterior chamber depth to peripheral corneal thickness, in addition to the iridocorneal angle using Image J software. Results: The correlation coefficient between values obtained by AS-OCT, and our fabricated portable scanning slit-light device was notably high. The results indicate that our portable device is equally reliable as the conventional nonportable slit-lamp microscope and AS-OCT for screening and evaluating eye diseases. Conclusions: Our fabricated device matches the functionality of the traditional slit lamp, offering a cost-effective and portable solution. Ideal for remote locations, healthcare facilities, or areas affected by disasters, our scanning slit-light device can provide easy access to initial eye examinations and supports digital eye healthcare initiatives.

3.
BMJ Case Rep ; 17(4)2024 Apr 19.
Artigo em Inglês | MEDLINE | ID: mdl-38642933

RESUMO

Pterygium is a benign, wing-shaped fibrovascular overgrowth of subconjunctival tissue that can encroach over the cornea. This condition usually occurs in individuals aged 20-40 years but is rarely seen in children. We report a case of an infant with Rubenstein-Taybi syndrome presenting with nebulo-macular corneal opacity and congenital pterygium. On examination under anaesthesia, bilateral infero-nasal nebulo-macular corneal opacity (6 × 5 mm) with a whitish pink tissue originating from nasal bulbar conjunctiva was noticed. The probe test was negative for this tissue. To the best of our knowledge, only two other cases of congenital pterygium have been reported in the literature. The presence of this anomaly supports the hypothesis of genetic factors having a role in the development of pterygium.


Assuntos
Túnica Conjuntiva/anormalidades , Opacidade da Córnea , Anormalidades do Olho , Pterígio , Síndrome de Rubinstein-Taybi , Lactente , Criança , Humanos , Pterígio/complicações , Pterígio/cirurgia , Pterígio/diagnóstico , Síndrome de Rubinstein-Taybi/complicações , Síndrome de Rubinstein-Taybi/diagnóstico , Síndrome de Rubinstein-Taybi/genética , Córnea/anormalidades
4.
Taiwan J Ophthalmol ; 14(1): 117-120, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38654997

RESUMO

The purpose of this study was to describe a case and clinical course of simultaneous anterior chamber phakic intraocular lens (AC-pIOL) removal, implantation of a posterior chamber phakic intraocular implantable collamer lens (ICL), and Descemet membrane endothelial keratoplasty (DMEK). This was a case report of a 44-year-old male with a unilateral decompensated cornea from a displaced Duet-Kelman lens on his left eye that underwent pIOL extraction and implantation of a posterior chamber phakic intraocular ICL and simultaneous DMEK. After 6 months, the cornea of the left eye had regained clarity, the Descemet membrane was graft stable, and the ICL implanted was centered with good vault. Postoperative anisometropia was avoided. There was no development of cataracts or other complications. The simultaneous pIOL extraction, ICL implantation, and DMEK in our case showed good results with full restoration of anterior segment anatomy and return of transparency of the cornea. The current case shows the feasibility of the simultaneous approach instead of sequential as an alternative for patients with endothelial disease associated with AC pIOLs, restoring vision and anatomy and also avoiding postoperative anisometropia.

5.
Vet Ophthalmol ; 2024 Mar 22.
Artigo em Inglês | MEDLINE | ID: mdl-38519851

RESUMO

An approximately 1.5-year-old mixed breed heifer was presented for evaluation and treatment due to ocular pain affecting the right eye secondary to a live nematode within the anterior chamber. Ophthalmic examination revealed marked blepharospasm, evidence of chronic keratitis, uveitis, and a single, white, approximately 2.5 cm long, 0.5 mm thick, living parasite. The heifer underwent general anesthesia, and the parasite was removed using passive aqueous humor outflow following a stab incision into the anterior chamber. Twenty-four hours after removal of the intraocular parasite, the heifer displayed a significant improvement in ocular comfort, corneal edema, and uveitis. The nematode was identified via genetic analyses as Parafilaria bovicola, a filarial parasite of cattle. The heifer was discharged 5 days following nematode removal with a marked improvement in all ocular signs and apparently normal vision. To the authors' knowledge, there are no previous reports of confirmed intraocular filariosis caused by P. bovicola in the veterinary literature, nor are there reports detailing surgical removal of intraocular parasites in bovids.

7.
Int Ophthalmol ; 44(1): 160, 2024 Mar 27.
Artigo em Inglês | MEDLINE | ID: mdl-38536560

RESUMO

PURPOSE: To compare anterior chamber angle (ACA) parameters measured by Anterior Segment Optical Coherence Tomography (ASOCT) and biometric parameters measured by Swept-Source (SS) OCT-based biometry among patients with suspected occludable angles and open angles. METHODS: An analytical, cross-sectional study was performed on subjects attending our ophthalmology outpatient department with suspected occludable angles (van Herick grades 0, 1, and 2) in group 1, and with open angles (van Herick grades 3 and 4) in group 2. Each subject underwent a complete ophthalmic examination to exclude any intraocular pathology like cataract. We recruited 128 eyes of 64 subjects, 34 in group 1 and 30 in group 2. Each eye was henceforth subjected to ASOCT (Spectralis, Heidelberg Engineering, Heidelberg) and SS-OCT-based optical biometry (IOL Master 700, Carl Zeiss Meditec AG). Anatomical parameters were recorded and compared between the two groups. RESULTS: The main outcome measures of the study included nine ASOCT parameters (central corneal thickness [CCT], lens vault, AOD750, ACA, TISA750 [nasal and temporal], and ACW) and five optical biometric parameters (CCT, ACD, WTW, LT, and axial length). We found a significant difference (p < 0.05) among all the anatomical parameters between the two groups, except CCT which was not significantly different (p = 0.297). CONCLUSIONS: ASOCT and SSOCT biometry overcome the challenges of gonioscopy and allow screening for angle closure disease in otherwise normal subjects. ASOCT may serve as an alternative to gonioscopy as it clearly separates occludable angles from open angles in a non-invasive and objective manner.


Assuntos
Glaucoma de Ângulo Fechado , Tomografia de Coerência Óptica , Humanos , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Pressão Intraocular , Glaucoma de Ângulo Fechado/diagnóstico , Glaucoma de Ângulo Fechado/patologia , Câmara Anterior/diagnóstico por imagem , Câmara Anterior/patologia , Biometria , Gonioscopia , Segmento Anterior do Olho/diagnóstico por imagem , Segmento Anterior do Olho/patologia
8.
BMJ Case Rep ; 17(3)2024 Mar 13.
Artigo em Inglês | MEDLINE | ID: mdl-38479826

RESUMO

A woman in her 60s presented with diminution of vision and redness in her right eye (OD) 1.5 months duration, 10 months post cataract surgery. The best-corrected visual acuity (BCVA) on the OD was fingers counting at 0.5 m. The anterior section of the OD demonstrated superior pre-Descemet's intrastromal bleeding, superior dense fibrovascular growth in the corneal mid-stroma and superior fibrovascular downgrowth measuring 5×5 mm in the anterior chamber. Along with topical prednisolone acetate (1%) suspension 4 times per day on a tapering dose, antivascular endothelial growth factor therapy was administered intrastromally and subconjunctivally in the superior bulbar conjunctiva near limbus (0.05 mL of 2.5 mg/0.1 mL at each site). Over the course of a week, the intrastromal bleed had completely stopped. Three months later, at the final follow-up, the BCVA had marginally improved to fingers counting 2 m, with a lingering 4×4 mm nebulomacular scar.


Assuntos
Extração de Catarata , Feminino , Humanos , Extração de Catarata/efeitos adversos , Substância Própria , Câmara Anterior , Imagem Multimodal
9.
Ophthalmic Res ; 67(1): 248-256, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38527448

RESUMO

INTRODUCTION: This study aimed to determine the interchangeability of bilateral anterior chamber depth (ACD) in intraocular lens (IOL) power calculations for cataractous eyes and refractive outcomes using the unaffected fellow eye's ACD in subluxated crystalline lenses. METHODS: The predicted postoperative spherical equivalent (SE) calculated using the Kane formula with and without fellow eye's ACD in 202 cataract patients was compared. Refractive outcomes of the newer formulas (the Kane, Barrett Universal II [BUII], and Pearl-DGS formulas) with affected eye's ACD and with unaffected fellow eye's ACD were compared in 33 eyes with lens subluxation (the affected eye) undergoing in-the-bag IOL implantation. The SD of the prediction error (PE) was assessed using the heteroscedastic method. RESULTS: In 202 paired cataractous eyes, no marked ACD difference was found bilaterally; the predicted SE obtained without the fellow eye's ACD was comparable with that calculated with the fellow eye one (p = 0.90), with a mean absolute difference of 0.03 ± 0.03 D. With the affected eye AL, keratometry, and ACD, the median absolute error (MedAE) was 0.38-0.64 D, and the percentage of PE within ±0.50 D was 30.30-57.58%. The unaffected eye's ACD improved the results (MedAE, 0.35-0.49 D; the percentage of PE within ±0.50 D, 54.55-63.64%). The SDs of the BUII (0.82 D) and Pearl-DGS formulas (0.87 D) with the affected eye's ACD were significantly larger than those of the Kane and Pearl-DGS formulas (both 0.69 D) with the unaffected eye's ACD. CONCLUSION: Bilateral ACD was interchangeable in IOL power calculation for cataractous eyes when using the Kane formula. Unaffected eye's ACD in lieu of affected eye's ACD can enhance the accuracy of newer formulas in patients with unilateral subluxated lenses undergoing in-the-bag IOL implantation.


Assuntos
Câmara Anterior , Subluxação do Cristalino , Lentes Intraoculares , Refração Ocular , Humanos , Masculino , Feminino , Idoso , Refração Ocular/fisiologia , Pessoa de Meia-Idade , Subluxação do Cristalino/cirurgia , Subluxação do Cristalino/diagnóstico , Subluxação do Cristalino/fisiopatologia , Adulto , Acuidade Visual , Estudos Retrospectivos , Óptica e Fotônica , Implante de Lente Intraocular/métodos , Biometria/métodos , Idoso de 80 Anos ou mais
10.
Parasit Vectors ; 17(1): 137, 2024 Mar 15.
Artigo em Inglês | MEDLINE | ID: mdl-38491528

RESUMO

BACKGROUND: After ivermectin became available, diethylcarbamazine (DEC) use was discontinued because of severe adverse reactions, including ocular reactions, in individuals with high Onchocerca volvulus microfilaridermia (microfilariae/mg skin, SmfD). Assuming long-term ivermectin use led to < 5 SmfD with little or no eye involvement, DEC + ivermectin + albendazole treatment a few months after ivermectin was proposed. In 2018, the US FDA approved moxidectin for treatment of O. volvulus infection. The Phase 3 study evaluated SmfD, microfilariae in the anterior chamber (mfAC) and adverse events (AEs) in ivermectin-naïve individuals with ≥ 10 SmfD after 8 mg moxidectin (n = 978) or 150 µg/kg ivermectin (n = 494) treatment. METHODS: We analyzed the data from 1463 participants with both eyes evaluated using six (0, 1-5, 6-10, 11-20, 21-40, > 40) mfAC and three pre-treatment (< 20, 20 to < 50, ≥ 50) and post-treatment (0, > 0-5, > 5) SmfD categories. A linear mixed model evaluated factors and covariates impacting mfAC levels. Ocular AEs were summarized by type and start post-treatment. Logistic models evaluated factors and covariates impacting the risk for ocular AEs. RESULTS: Moxidectin and ivermectin had the same effect on mfAC levels. These increased from pre-treatment to Day 4 and Month 1 in 20% and 16% of participants, respectively. Six and 12 months post-treatment, mfAC were detected in ≈5% and ≈3% of participants, respectively. Ocular Mazzotti reactions occurred in 12.4% of moxidectin- and 10.2% of ivermectin-treated participants without difference in type or severity. The risk for ≥ 1 ocular Mazzotti reaction increased for women (OR 1.537, 95% CI 1.096-2.157) and with mfAC levels pre- and 4 days post-treatment (OR 0: > 10 mfAC 2.704, 95% CI 1.27-5.749 and 1.619, 95% CI 0.80-3.280, respectively). CONCLUSIONS: The impact of SmfD and mfAC levels before and early after treatment on ocular AEs needs to be better understood before making decisions on the risk-benefit of strategies including DEC. Such decisions should take into account interindividual variability in SmfD, mfAC levels and treatment response and risks to even a small percentage of individuals.


Assuntos
Volvo Intestinal , Macrolídeos , Onchocerca volvulus , Oncocercose , Animais , Feminino , Humanos , Câmara Anterior , República Democrática do Congo , Método Duplo-Cego , Gana , Ivermectina/efeitos adversos , Libéria , Microfilárias , Onchocerca , Oncocercose/tratamento farmacológico , Masculino
11.
Clin Ophthalmol ; 18: 699-712, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38468913

RESUMO

Background: We studied the kinetic phenomenon of an airbag impact on eyes with different axial lengths using finite element analysis (FEA) to sequentially determine the physical and mechanical responses of intraocular segments at various airbag deployment velocities. Methods: The human eye model we created was used in simulations with the FEA program PAM-GENERISTM. The airbag was set to impact eyes with axial lengths of 21.85 mm (hyperopia), 23.85 mm (emmetropia) and 25.85 mm (myopia), at initial velocities of 20, 30, 40, 50 and 60 m/s. The deformation rate was calculated as the ratio of the length of three segments, anterior chamber, lens and vitreous, to that at the baseline from 0.2 ms to 2.0 ms after the airbag impact. Results: Deformation rate of the anterior chamber was greater than that of other segments, especially in the early phase, 0.2-0.4 ms after the impact (P < 0.001), and it reached its peak, 80%, at 0.8 ms. A higher deformation rate in the anterior chamber was found in hyperopia compared with other axial length eyes in the first half period, 0.2-0.8 ms, followed by the rate in emmetropia (P < 0.001). The lens deformation rate was low, its peak ranging from 40% to 75%, and exceeded that of the anterior chamber at 1.4 ms and 1.6 ms after the impact (P < 0.01). The vitreous deformation rate was lower throughout the simulation period than that of the other segments and ranged from a negative value (elongation) in the later phase. Conclusion: Airbag impact on the eyeball causes evident deformation, especially in the anterior chamber. The results obtained in this study, such as the time lag of the peak deformation between the anterior chamber and lens, suggest a clue to the pathophysiological mechanism of airbag ocular injury.

12.
Diagnostics (Basel) ; 14(5)2024 Mar 06.
Artigo em Inglês | MEDLINE | ID: mdl-38473032

RESUMO

The VEMoS-AXL system is a new optical biometer based on spectral domain optical coherence tomography (SD-OCT) that has been tested in terms of intrasession repeatability and compared with a swept-source optical coherence tomography biometer (SS-OCT), which is recognized as the gold standard for the performance of an agreement analysis. A biometric analysis was performed three consecutive times in 120 healthy eyes of 120 patients aged between 18 and 40 years with the SD-OCT system, and afterwards, a single measurement was obtained with the SS-OCT system. Within-subject standard deviations were 0.004 mm, 4.394 µm, and 0.017 mm for axial length (AL), central corneal thickness (CCT), and anterior chamber depth (ACD) measures obtained with the SD-OCT biometer, respectively. The agreement between devices was good for AL (limits of agreement, LoA: -0.04 to 0.03 mm) and CCT (LoA: -4.36 to 14.38 µm), whereas differences between devices were clinically relevant for ACD (LoA: 0.03 to 0.21 mm). In conclusion, the VEMoS-AXL system provides consistent measures of anatomical parameters, being most of them interchangeable with those provided by the SS-OCT-based gold standard.

13.
Int Ophthalmol ; 44(1): 113, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38407652

RESUMO

PURPOSE: To evaluate anterior and posterior segment parameters in the eyes of patients with systemic sclerosis (SSc) and examine the effect of disease and disease subtypes on these parameters. METHODS: This cross-sectional study included 54 eyes of 27 SSc patients and 54 eyes of 27 age- and sex-matched healthy controls. In addition to a complete ophthalmologic examination, all patients were examined using a Scheimpflug camera, specular microscopy, and spectral domain optical coherence tomography. RESULTS: The mean age of the patients was 52.5 ± 11.4 years and 19 patients were female. Anterior chamber volume, central corneal thickness, and central macular thickness (CMT) were significantly lower in the eyes of SSc patients compared to healthy controls (p = 0.01, p = 0.03, and p = 0.006, respectively). When evaluated according to SSc subtype, CMT was lower in diffuse SSc patients (p = 0.001), while mean retinal nerve fiber layer (RNFL) and inferior quadrant RNFL values were lower in limited SSc (p = 0.003 and p = 0.005, respectively). CONCLUSION: In the eyes of patients with SSc, some ocular parameters may show decreases compared to healthy individuals, presumably secondary to disease-related vasculopathy and fibrosis. CMT and RNFL parameters may be affected differently according to disease subtype.


Assuntos
Escleroderma Sistêmico , Humanos , Feminino , Adulto , Pessoa de Meia-Idade , Masculino , Estudos Transversais , Escleroderma Sistêmico/complicações , Escleroderma Sistêmico/diagnóstico , Retina , Câmara Anterior , Tomografia de Coerência Óptica
14.
BMC Ophthalmol ; 24(1): 87, 2024 Feb 26.
Artigo em Inglês | MEDLINE | ID: mdl-38408954

RESUMO

BACKGROUND: To evaluate the difference in anterior chamber depth (ACD) between two eyes among keratoconus patients with binocular very asymmetric ectasia (VAE) and to explore the influencing factors. METHODS: The corneal curvature and ACD in both eyes of patients with VAE were measured by Sirius (version 3.2, CSO, Italy) at the following points: corneal vertex, maximum curvature (apex), and the 1.5 mm, 2.5 mm, and 3.5 mm superior-, inferior-, nasal-, temporal-paracentral from center. The mean pupil power (MPP) and corneal morphology parameters were also measured. Correlations between ACD and curvature and morphology parameters were analyzed by linear regression. RESULTS: 172 eyes of 86 patients (9 to 45 years) were classified into the VAE-N (n = 86) group and the VAE-E group (n = 86) based on the corneal morphology. The central (3.32 ± 0.27 mm versus 3.43 ± 0.29 mm, P < 0.001) and paracentral ACDs increased significantly in the VAE-E group, and the corneal morphology parameters were also significantly higher. The central ACD was significantly correlated with the MPP (r = 0.465), KVf/b (Keratoconus Vertex front/back) (r = 0.306, r = 0.327), and BCVf/b (Baiocchi Calossi Versaci front/back) (r = 0.356, r = 0.416). Linear regression showed good relationships between △ACD and △MPP (R2 = 0.429) and △KVf/b (R2 = 0.504, R2 = 0.536). CONCLUSIONS: The ACD was larger in the VAE-E group. The difference in ACD between the VAE-E and VAE-N groups was significantly correlated with corneal curvature and the extent of corneal elevation, indicating the influences of both the corneal magnification effect and corneal ectasia on ACD.


Assuntos
Ceratocone , Humanos , Ceratocone/complicações , Ceratocone/diagnóstico , Topografia da Córnea , Paquimetria Corneana , Dilatação Patológica , Córnea , Câmara Anterior
15.
Int Ophthalmol ; 44(1): 62, 2024 Feb 12.
Artigo em Inglês | MEDLINE | ID: mdl-38345699

RESUMO

PURPOSE: This study evaluated the relationship between refractive outcomes and postoperative anterior chamber depth (ACD, measured from corneal epithelium to lens) measured by swept-source optical coherence tomography (SS-OCT), optical low-coherence reflectometry (OLCR), and Scheimpflug devices under the undilated pupil. METHODS: Patients undergoing cataract phacoemulsification with intraocular lens (IOL) implantation in a hospital setting were enrolled. Postoperative ACD (postACD) was performed with an SS-OCT device, an OLCR device, and a Scheimpflug device at least 1 month after cataract surgery. After adjusting the mean predicted error to 0, differences in refractive outcomes were calculated with the Olsen formula using actual postACD measured from 3 devices and predicted value. RESULTS: Overall, this comparative case study included 69 eyes of 69 patients, and postACD measurements were successfully taken using all 3 devices. The postACD measured with the SS-OCT, OLCR, and Scheimpflug devices was 4.59 ± 0.30, 4.50 ± 0.30, and 4.54 ± 0.32 mm, respectively. Statistically significant differences in postACD were found among 3 devices (P < 0.001), with intraclass correlation coefficients (ICCs) and Bland-Altman showing good agreement. No significant difference in median absolute error was found with the Olsen formula using actual postACD obtained with 3 devices. Percentage prediction errors were within ± 0.50 D in 65% (OLCR), 70% (Scheimpflug), and 67% (SS-OCT) calculated by actual postACD versus 64% by predicted value. CONCLUSION: Substantial agreement was found in postACD measurements obtained from the SS-OCT, OLCR, and Scheimpflug devices, with a trend toward comparable refractive outcomes in the Olsen formula. Meanwhile, postACD measurements may be potentially superior for the additional enhancement of refractive outcomes.


Assuntos
Catarata , Cristalino , Lentes Intraoculares , Humanos , Câmara Anterior/diagnóstico por imagem , Comprimento Axial do Olho , Refração Ocular , Catarata/diagnóstico , Tomografia de Coerência Óptica/métodos , Biometria/métodos , Reprodutibilidade dos Testes
16.
Int Ophthalmol ; 44(1): 34, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38332205

RESUMO

PURPOSE: To explore the associations between central anterior chamber depth (CACD) and other anterior segment biometric parameters and to determine the possible determinants of CACD in short, normal, and long eyes. METHODS: The biometric data of pre-operation patients aged 50-80 years with coexisting cataract and primary angle-closure disease or senile cataract were reviewed. Axial length (AL), CACD, lens thickness (LT), central corneal thickness (CCT), and white-to-white distance (WTW) were measured by Lenstar optical biometry (Lenstar 900). The data of 100 normal eyes (AL = 22 to 26 mm), 100 short eyes (AL ≤ 22 mm), and 100 long eyes (AL ≥ 26 mm) were consecutively collected for subsequent analyses. RESULTS: The mean age of the subjects was 66.60 ± 7.85 years, with 25.7% of the sample being men. Both CACD and WTW were found to be smallest in short eyes and were smaller in normal eyes than in long eyes (F = 126.524, P < 0.001; F = 28.458, P < 0.001). The mean LT was significantly thicker in short eyes than in normal and long eyes (4.66 mm versus 4.49 mm versus 4.40 mm; F = 18.099, P < 0.001). No significant differences were observed in CCT between the three AL groups (F = 2.135, P = 0.120). Stepwise regression analysis highlighted AL, LT, and WTW as three independent factors associated with CACD in the normal AL group. In the short AL group and long AL group, LT and WTW were independent factors associated with CACD. CONCLUSIONS: CACD increases as AL elongates and reaches a peak when AL exceeds 26 mm. Furthermore, CACD showed inverse correlation with LT and positive correlation with WTW. A relatively small WTW results in an anteriorly positioned lens, and thus, a decrease in CACD.


Assuntos
Catarata , Cristalino , Lentes Intraoculares , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Feminino , Cristalino/diagnóstico por imagem , Catarata/complicações , Catarata/diagnóstico , Biometria/métodos , Câmara Anterior/diagnóstico por imagem , Comprimento Axial do Olho
17.
Int Ophthalmol ; 44(1): 35, 2024 Feb 08.
Artigo em Inglês | MEDLINE | ID: mdl-38332452

RESUMO

PURPOSE: To determine the effect of phacoemulsification surgery, which is one of the types of cataract surgery by using ultrasonic power to break up the crystalline lens and clean it with vacuum, on anterior chamber flare (ACF) and choroidal vascular index (CVI). METHODS: For this cross-sectional study, patients were included if they had cataract with nucleus hardness grade 2 or 3, no systemic inflammatory disease, and not use of anti-inflammatory drugs/prostaglandins preoperatively. ACF using a laser flare meter and CVI in patients underwent uncomplicated phacoemulsification was recorded preoperatively, on the postoperative 1st day, 1st week, and 1st month. RESULTS: Fifty-six eyes were included. ACF was 9.00 ± 2.90 ph/ms preoperatively. Although ACF increased significantly on postoperative day-1 (39.38 ± 23.31ph/ms) and decreased gradually until the 1st month (14.03 ± 6.03ph/ms) after the operation, it was still significantly higher at the 1st month (p < 0.001). Macular and peripapillary CVI increased significantly on postoperative day-1 (0.64 ± 0.03/0.63 ± 0.05) and week-1 (0.64 ± 0.04/0.62 ± 0.04) (p = 0.01, p < 0.001); the postoperative 1st month was similar to the preoperative one (0.59 ± 0.06/0.58 ± 0.06). The relationship between the change in ACF and the change in CVI was not significant. CONCLUSION: Phacoemulsification causes raises in ACF and CVI due to increased intraocular inflammation. The fact that ACF was significantly higher in postoperative month-1 and CVI returned to its preoperative value suggests that the effect of uncomplicated phacoemulsification surgery on the increase in inflammation in the anterior segment lasts longer than in the posterior segment. These results suggest that ACF and CVI follow-up may be clinically important in the follow-up of postoperative inflammation.


Assuntos
Catarata , Facoemulsificação , Humanos , Facoemulsificação/efeitos adversos , Facoemulsificação/métodos , Estudos Transversais , Complicações Pós-Operatórias/diagnóstico , Inflamação/diagnóstico , Inflamação/etiologia , Catarata/complicações , Câmara Anterior
18.
Clin Ophthalmol ; 18: 351-360, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38332905

RESUMO

Purpose: Ocular parameters are not only useful for diagnosing diseases but also for guiding treatment approaches. A lot of previous studies have reported ocular parameters and its relations before cataract surgery. However, despite ethnic differences in ocular biometry, few reports have dealt with Japanese. Hence, this retrospective cross-sectional study aimed to measure parameters of preoperative cataract patients and examines the correlations between each parameter in Japanese elderly people. Patients and Methods: The 210 subjects had their ocular axial lengths measured with OA-2000. The endpoints were ocular axial length (AL), central corneal thickness (CCT), average anterior corneal radius of curvature (CR), white-to-white (WTW), anterior chamber depth (ACD), and lens thickness (LT). Our analyses utilized the eye with the longer AL in each person. Each parameter was analyzed for correlations in a round-robin manner. Regression analyses were performed on parameters correlated with AL. Results: The parameters correlated with AL were CR (r = 0.33, P < 0.0001), WTW (r = 0.29, P < 0.0001), ACD (r = 0.59, P < 0.0001), and LT (r = -0.30, P < 0.0001). These parameters related to AL in all simple regression equations (CR (P < 0.0001), WTW (P = 0.0002), ACD (P < 0.0001), LT (P = 0.0001)). In multiple regression analyses, CR, ACD, and LT might relate to AL (CR (P = 0.0002), ACD (P < 0.0001), LT (P = 0.018)). LT tended to be thinner as AL increased, while CR, WTW, and ACD tended to increase. Conclusion: This information may be useful in developing strategies for ophthalmic surgery, as it provides information on the location of intraocular tissues. Various parameters have been used in intraocular lens (IOL) power calculations in recent years and knowledge of the interrelationship among parameters may be useful in determining IOL power according to ethnicity in the future.

19.
Vet Ophthalmol ; 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38318722

RESUMO

OBJECTIVE: The objective of the study was to evaluate visual outcomes between medical treatment alone (MED) and Ahmed glaucoma valve implantation (AGVI) in Shiba dogs with primary angle closure glaucoma (PACG). PROCEDURES: Records of 65 Shiba dogs (104 eyes) with PACG were retrospectively reviewed. Vision was assessed qualitatively using both the menace response and maze testing. The significance of age, sex, intraocular pressure (IOP), and duration of clinical signs (≤72 h or >72 h) at first presentation (V1) was assessed. Eyes with vision at V1 were divided into groups according to subsequent treatment method (MED versus AGVI), and vision as a survival outcome was compared between group by the Kaplan-Meier method. RESULTS: At V1, 65 eyes (62.5%) of 54 dogs had vision. There was no statistically significant difference in age or sex on the presence of vision at V1. Median IOP was higher in blind (52 mmHg) compared to sighted eyes (28 mmHg) (p < .001). Eyes presenting in ≤72 h of the onset of clinical signs were more likely to have vision (86.7%) compared to those presenting after 72 h (44.1%) (p < .001). By the Kaplan-Meier analysis, the cumulative visual retention rate was significantly higher with AGVI than with MED (69.2% vs. 7.7%; p < .01) at 12 months. The median time to visual loss was 39.9 months with AGVI vs. 1.7 months with MED. CONCLUSIONS: AGVI resulted in better visual outcomes than MED and should be considered in Shiba dogs with PACG that are visual at the time of presentation and suitable for surgery.

20.
Int Ophthalmol ; 44(1): 15, 2024 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-38321260

RESUMO

PURPOSE: This study aims to investigate the influence of anterior chamber depth (ACD) and vault on the anterior chamber angle (ACA) morphology in myopic individuals implanted with posterior chamber phakic intraocular lenses. METHODS: This retrospective case series involved 231 eyes receiving a 13.2-mm implantable collamer lens (ICL). Preoperative anterior chamber anatomy was assessed using anterior segment optical coherence tomography (AS-OCT) and optical tomography, while postoperative evaluation employed AS-OCT. ACA morphology was characterized pre- and postoperatively through trabecular iris angle (TIA750), ACA distance opening (AOD750) and trabecular iris space area (TISA750). The influence of ACD and vault was examined by categorizing the sample into ACD (shallow, average and deep) and vault (low, optimal and high) groups. RESULTS: Preoperative ACA morphology varied based on ACD, with shallower ACDs exhibiting narrower TIA750, smaller AOD750 and TISA750. ICL implantation induced greater ACA narrowing more in the deep ACD group (TIA750 = 20.1 degrees; AOD750 = 0.82 mm and TISA750 = 0.44 mm2) compared to the shallow ACD group (TIA750 = 15.2 degrees; AOD750 = 0.44 mm and TISA750 = 0.21 mm2). Postoperatively, deeper ACDs showed larger ACAs. Increasing vault magnitude led to increased ACA narrowing, with the low vault group exhibiting smaller closure (TIA750 = 14.3 degrees; AOD750 = 0.56 mm and TISA750 = 0.29 mm2) compared to the high vault group (TIA750 = 20.8 degrees; AOD750 = 0.73 mm and TISA750 = 0.36 mm2). The magnitude of ACA narrowing associated with the vault had a consistent effect across different ACD groups. CONCLUSIONS: Posterior chamber intraocular lens implantation results in ACA narrowing, the extent of which is contingent upon preoperative anterior chamber and ACA morphology, with additional influence from vault magnitude.


Assuntos
Segmento Anterior do Olho , Glaucoma de Ângulo Fechado , Humanos , Implante de Lente Intraocular , Estudos Retrospectivos , Pressão Intraocular , Glaucoma de Ângulo Fechado/cirurgia , Câmara Anterior , Tomografia de Coerência Óptica/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...